My Account

Microprocessor Flame Photometer LJ-1382

Microprocessor Flame Photometers Model:LJ-1382 comes with Flame Failure detection and Auto Gas Cutoff Facility. In case of power failure, the gas cuts off automatically. In case the flame goes off accidently during work, the flame failure alarm sounds a

Rating :

Microprocessor Flame Photometer LJ-1382 Features ·         Microprocessor Based with Printer Interface ·       &nb...
$ 740.00
GST : 0.00%
Shipping : $ 0.00 More Detail
Quantity
 
 
Product Type : Industrial


Seller Store Details

Store Not Available

Microprocessor Flame Photometer LJ-1382

Features

·         Microprocessor Based with Printer Interface

·         Auto Gas Cutoff

·         Auto Flame Failure Detection

·         Four Measurements in Single Aspiration

·         Setup Storage Facility

·         Sample Data Storage Facility

·         Curve Calibration Programmability Using Maximum of 25 Standards

·         Multiple Calibration Curve Saving Facility

·         Data Processing Through Curve Fitting Techniques, Least Square, Quadratic

·         Online Help Key

·         Direct Results in ppm and meq

·         Useful for Medical & Soil Testings

Image-zoom

Microprocessor Flame Photometers Model:LJ-1382 comes with Flame Failure detection and   Auto Gas Cutoff Facility. In case of power failure, the gas cuts off automatically. In case the flame goes off accidently during work, the flame failure alarm sounds after a few seconds.

Microprocessor Flame Photometers Model : LJ-1382 are used for the determination of Sodium, Potassium, Calcium, Lithium & Barium. They uses the latest microcontroller technology and advanced engineering techniques so as to give enhanced accuracy and reproducibility. They have  soft touch membrane keys for ease of operation. The solution is aspirated through an atomizer. Air, sample and the fuel are mixed in the mixing chamber which is then sprayed as a very fine mist into the    flame. Radiations from the flame passes through a specific narrow band interference filter and pass to the photo-detector. The final results are displayed on the 20 x 4 alphanumeric LCD. The standard model comes with 2 filters (Na & K). Additional filters Ca & Li are optional at extra cost.

In both the models, Calibration can be done with up to 25 standards of user choice(5 point for each element) and non-linearity correction is provided through an automatic curve fitting software. Multiple Calibration Curves  can be stored in the memory. Facility has been provided for re-standardization with a single standard, thereby, eliminating the need of multiple standards once a calibration has been performed.

Specifications

Model

LJ-1382

Three Modes

General

Serum

Urine

Range

Na: 0 – 100 ppm
Upto 250 meq/l, 1:100 dil
K: 0 – 100 ppm
Upto 250 meq/l, 1:100 dil
Ca: 0 – 100 ppm
Upto 250 meq/l, 1:100 dil
Li: 0 – 100 ppm

Na: 0 – 200
1:100 dil
K: 0 – 10
1:100 dil

Li: 0 – 2
1:5 dil

Na: 0 – 250
1:100 dil
K: 0 – 100
1:100 dil
Ca: 0 – 10
1:2 dil

Sensitivity

General: Na: 0.5 ppm, K: 0.5 ppm, Li: 0.5 ppm, Ca: 15 ppm

Filters

Na & K supplied (Ca & Li are optional at extra cost)

Resolution

0.1 ppm/meq

Reproducibility

< 1% coefficient of variation for 20 consecutive samples using 10 ppm Na set as maximum standard

Curve Fit Accuracy

< 2% error when 3 ppm Na/K and 5 ppm Li are set as maximum standards

Display

20 x 4 alphanumeric LCD with backlit

Average Time

In-built in software

Flame System

LPG and dry oil free air

Detector

Silicon pho